The AirLink HEPA Absolute Filters they are developed with advanced technology to guarantee the highest efficiency in the removal of ultrafine particles in environments that require rigorous pollution control.
Each filter is produced with a filter element made of glass microfiber paper precisely folded to increase the capture area and optimize airflow. The frames are available in galvanized sheet, aluminum the stainless steel, with EPDM seal depending on the application’s needs: at the air inlet, air outlet, or on both sides.
All filters are subjected to individual tests in our own laboratory using aerosol D.O.P. / P.A.O…and electronic particle counting, guaranteeing quality, leak-proofness and reliability in accordance with standards DIN EN 1822 and NBR ISO 29463-1:2013.
Dimensions em mm | Caudal m³/h | Weight Kg | ||
| B | H | P | ||
| 305 | 305 | 78 | 260 | 1,5 |
| 305 | 610 | 78 | 540 | 2,5 |
| 457 | 457 | 78 | 600 | 2,5 |
| 610 | 610 | 78 | 1100 | 3,5 |
| 610 | 762 | 78 | 1400 | 4 |
| 610 | 915 | 78 | 1700 | 4,5 |
| 610 | 1220 | 78 | 2200 | 5,7 |
| 305 | 610 | 292 | 1600 | 9,5 |
| 610 | 610 | 292 | 2400 | 15,5 |
| 610 | 610 | 292 | 3200 | 16,5 |
| 610 | 610 | 292 | 4000 | 17 |
| 610 | 762 | 292 | 3750 | 20 |
| Recommended final pressure drop (Pa): 600 | ||||
Other sizes available upon request. Please consult our technical-sales department.
High-efficiency air filter classification | ||||
EPA, HEPA and ULPA according to EN 1822-2009 | ||||
| Global Values | Local Values | |||
| Class | Efficiency % | Penetration % | Efficiency % | Penetration % |
| E10 | ≥ 85 | ≤ 15 | ─ | ─ |
| E11 | ≥ 95 | ≤ 5 | ─ | ─ |
| E12 | ≥ 99,5 | ≤ 0,5 | ─ | ─ |
| H13 | ≥ 99,95 | ≤ 0,05 | ≥ 99,75 | ≤ 0,25 |
| H14 | ≥ 99,995 | ≤ 0,005 | ≥ 99,975 | ≤ 0,025 |
High-efficiency air filter classification – EPA, HEPA and ULPA according to NBR ISO 29463-1:2013 | ||||
| Global Values | Local Values | |||
| Class | Efficiency % | Penetration % | Efficiency % | Penetration % |
| ISO 15 E | ≥ 95 | ≤ 5 | ─ | ─ |
| ISO 20 E | ≥ 99 | ≤ 1 | ─ | ─ |
| ISO 25 E | ≥ 99,5 | ≤ 0,5 | ─ | ─ |
| ISO 30 E | ≥ 99,90 | ≤ 0,1 | – | – |
| ISO 35 H | ≥ 99,95 | ≤ 0,05 | ≥ 99,75 | ≤ 0,25 |
| ISO 40 H | ≥ 99,99 | ≤ 0,01 | ≥ 99,95 | ≤ 0,05 |
| ISO 45 H | ≥ 99,995 | ≤ 0,005 | ≥ 99,975 | ≤ 0,025 |
| ISO 50 U | ≥ 99,999 | ≤ 0,001 | ≥ 99,995 | ≤ 0,005 |
| ISO 55 U | ≥ 99,999 5 | ≤ 0,000 5 | ≥ 99,997 5 | ≤ 0,002 5 |
| ISO 60 U | ≥ 99,999 9 | ≤ 0,000 1 | ≥ 99,997 5 | ≤ 0,000 5 |
| ISO 65 U | ≥ 99,999 95 | ≤ 0,000 05 | ≥ 99,999 75 | ≤ 0,000 25 |
| ISO 70 U | ≥ 99,999 99 | ≤ 0,000 01 | ≥ 99,999 9 | ≤ 0,000 1 |
| ISO 75 U | ≥ 99,999 995 | ≤ 0,000005 | ≥ 99,999 9 | ≤ 0,000 1 |
For filters used in hoods contaminated with chemotherapeutic drugs or hazardous materials, disposal must follow the rules for special chemical waste, under the responsibility of the user, through companies authorized by the competent environmental bodies.
AirLink Filters – Technology, reliability and efficiency for environments that cannot tolerate failure.
Get in touch with our technical team and discover the best filtration solution for your application.